MCA9-MCE9 TEST RESULTS

MCA9 Through-hole MCE9 Through-hole
Test conditions Typical variation of nominal resistance Test conditions Typical variation of nominal resistance
Damp heat 500 h. at 40°C and 95% RH +5%, -2% 500 h. at 40°C and 95% RH ±2%
Thermal cycles 16 h at 85ºC, plus 2 h at –25ºC ±2.5% 16 h at 90ºC, plus 2 h at –40ºC ±2%
Load life 1.000 h. at 50°C +0%; -6% 1.000 h. at 70°C ±2%
Mechanical life 1.000 cycles at 10 c.p.m. and at 23°C ± 2°C ±3% 1.000 cycles at 10 c.p.m. and at 23°C ± 2°C ±3%
Storage (3 years) 3 years at 23°C ± 2°C ±3% 3 years at 23°C ± 2°C ±1%